Zichai_Logo-removebg-preview_edited_edited.png
Screenshot 2026-11-05 161502.png

Model

YM11000T3

Rated frequency (Hz)

50

Rated output (kW)

8

Max. output (kW)

9

Rated voltage (V)

220/380

Rated currency (A)

36.3/15.2

Rated rotation speed (r/min)

3000

Phase NO.

3 phase

Power factor (CosΦ)

0.8

Insulation Grade

F

Pole number

2

Excitation mode

Self-excitation & constant voltage (AVR)

Panel Type

General panel

Receptacle

Two receptacles

DC12V output

Connection pole output

Overall dimension (LxWxH) (mm)

1160*695*880

Dry weight (kg)

205

Working assorting weight (kg)

215

Noise level (7m) [d B(A)]

77

Structure type

Silent type

Engine Model

YM1100FE

Engine Type

Single cylinder, vertical, four-stroke, direct injection, air -cooled

Cylinder NO.- bore x stroke (mm)

1-100x85

Displacement (ml)

667

Rated power [kW (r/min)]

10.5/3000

Compression ratio

19:01

Lubrication system

Pressure splashed

Starting system

Electric Starter

Fuel type

0#(summer)-10#(winter)-35#(chillness)diesel

Lube oil brand

CD grade or SAE10W-30,15W-40

Lube capacity (L)

2.0

Starting motor capacity (V-kW)

12V 1.6kW

Charging generator capacity (V-A)

12V 8.3A

Battery capacity (v-Ah)

12V 36AH

Fuel consumption (glkw*h)

≤300

Fuel tank capacity (L)

25

Continuous running time (hr)

6.5

Screenshot 2026-11-05 172956.png

ENGINE

Feature

Description

Air-cooled structure, no water refilling, extremely strong environmental adaptability

No radiator, no water-cooling pipes, and no need to top up coolant. Works in the field, on construction sites, at high altitudes, and in low-temperature environments; resistant to freezing, and can even operate when installed at an angle. Maintenance saves you the hassle of changing water or adding antifreeze ideal for mobile equipment and remote sites without a water source.

Single-cylinder design, simple, highly reliable and easy to maintain

Fewer parts mean a lower failure rate; the injector, piston, cylinder liner and filter are all common standard parts, so spares are inexpensive. Maintenance is simple and can be carried out on site, keeping after-sales costs low well suited to overseas markets and job sites.

High torque, excellent heavy-load performance and outstanding fuel economy

The diesel engine's high compression ratio delivers ample low-speed torque and strong load-carrying capability. Compared with a petrol engine of the same power, it consumes less fuel, saving fuel during prolonged operation ideal for continuous loads such as generators and irrigation pumps.

Stable cooling system with cooling fan + air guide hood design

The flywheel is fitted with a large cooling fan, and the integrated air guide hood directs airflow for forced-air cooling, keeping the temperature rise under control during continuous operation. A protective guard shields the fan from debris, improving safety in the field.

Compact overall design with controllable size and weight

The single-cylinder air-cooled design keeps the unit small and space-saving, making assembly and handling easy and convenient to build into a mobile generator set.

Export quality

ZICHAI brand with English branding, exported to 100+ countries and compliant with export standards; the company holds CE, ISO and Euro 5 emission certificates.

Screenshot 2026-11-06 093126.png

DIGITAL PANELS

Feature

Description

Multi-function digital meter HJ-301

Digital voltmeter that simultaneously displays voltage and running hours, making it convenient to record the unit's operating time and manage maintenance schedules more accurate readings than traditional analog meters.

Pre-wired for ATS automatic transfer switch

Equipped with an ATS switch; automatic transfer function optional. On mains power failure the unit starts automatically to supply power, and shuts down automatically when mains power is restored deal for standby power applications (shops, construction sites, machine room backup power).

Key start for safe operation

Three-position key switch: OFF → ON → START, following the standard diesel generator starting logic. The key can be removed to prevent unauthorized personnel from accidentally starting the unit, making equipment management safer.

Rugged panel structure for easy unit assembly

Metal panel with pre-drilled mounting holes, suitable for open-skid/silent diesel generator assembly. Modular components make later repair and parts replacement easy; the circuit breaker, digital meter and sockets are all common standard parts, keeping replacement costs low.

Comprehensive safety protection

Delixi three-phase air circuit breaker: overload, short-circuit and short-circuit protection in the event of any abnormal load it cuts off the AC power immediately to protect the generator and downstream equipment. OIL ALERT oil-level warning lamp: alerts when oil is insufficient or oil pressure is low, prompting shutdown to prevent cylinder scuffing/damage to the diesel engine. DC circuit fitted with a FUSE to protect the 12V starting control circuit.

Dual AC output for strong power-supply compatibility

Blue socket: AC220V single-phase; red socket: AC380V three-phase single phase and three phase loads can be used simultaneously. Industrial CEE waterproof sockets with dust-protection caps provide dust and water protection outdoors and on construction sites, with reliable plug-in connections.

TECHNICAL INSTRUCTION

 a. The generator set shall be capable of running continously for 10 hours at a load of 9kW

 b. The generator set shall be fitted with an ATS controller. In case of utility grid power outage, the unit shall auto-start within 8 to 12 seconds. Upon restoration of utility grid supply, the unit shall automatically stop.

 c. The maximum permissable step-on load of the unit is 3kW

bottom of page